LOCTITE FREKOTE 770 NC - 1 L (mold release agent)

LOCTITE FREKOTE 770 NC - 1 L  (mold release agent) (IDH.380973)

Product description:
LOCTITE FREKOTE 770-NC offers excellent release for various molding applications. LOCTITE FREKOTE 770-NC can be used for the release of epoxies, polyester resins, vinyl ester resins, thermoplastics, adhesives, and rotationally molded plastics. This product is particulary well suited for tougher to release processes such as filament winding and non gel coated polyester and fiberglass molding. Further information about the product: biuro@woronko-kleje.pl

Directions for use:
1. LOCTITE FREKOTE 770-NC can be applied to mold surfaces at room temperature up to 60°C by spraying, brushing or wiping with a clean lint-free, cloth. When spraying ensure a dry air source is used or use an airless spray system. Always use in a well ventilated area.
2. Wipe or spray on a smooth, thin, continuous, wet film. Avoid wiping or spraying over the same area that was just coated until the solvent has evaporated. If spraying, hold nozzle 20 to 30cm from mold surface. It is suggested that small areas be coated, working progressively from one side of the mold to the other.
3. Initially, apply 2 to 3 base coats allowing 5 to 10 minutes between coats for solvent evaporation .
4. Allow the final coat to cure for 5 to 10 minutes at 22°C.
5. Maximum releases will be obtained as the mold surface becomes conditioned to LOCTITE FREKOTE 770-NC. Performance can be enhanced by re-coating once, after the first few initial pulls.
6. When any release difficulty is experienced, the area in question can be "touched-up" by re-coating the entire mold surface or just those areas where release difficulty is occurring.
7. NOTE: LOCTITE FREKOTE 770-NC is moisture sensitive, keep container tightly closed when not in use. The product should always be used in a well ventilated area.
8. Precaution: Users of closed mold systems (rotomolding) must be certain that solvent evaporation is complete and that all solvent vapors have been ventilated from the mold cavity prior to closing the mold. An oil-free compressed air source can be used to assist in evaporation of solvents and ventilation of the mold cavity.

Storage:
The product is classified as flammable and must be stored in an appropriate manner in compliance with relevant regulations. Do not store near oxidizing agents or combustible materials. Store product in the unopened container in a dry location. Storage information may also be indicated on the product container labelling. Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties. Material removed from containers may be contaminated during use. Do not return product to the original container. Henkel cannot assume responsibility for product which has been contaminated or stored under conditions other than those previously indicated.

Parameters:
  • Appearance : clear, colorless
  • Application Temperature : 15 to 60 °C
  • Specific gravity at 25 °C : 0,715 to 0,725
  • Odour : weak
  • Cured Thermal Stability : ≤400 °C
  • No contaminating transfer
  • High gloss finish
  • High slip
  • No mold build-up

    Full technical information can be found in the technical data sheet
  • Assortment