LOCTITE PC 6261 YL big foot, 1K - 6,36kg (anti-slip resin, yellow)
No.
IDH.2236679
Product description:
LOCTITE PC 6261 is a single-component epoxy non-slip floor and deck coating that is designed for application in areas of heavy pedestrian traffic or light rolling traffic under typical dry service temperatures of -29 to 60°C (-20 to 140F). This high performance safety coating is both easy and fast to apply. Typical applications include a non-slip finish for concrete and steel ramps, walkways, locker rooms, loading docks, marine applications, machine rooms assembly areas and stairs. Further information about the product: biuro@woronko-kleje.pl
Steps to achieve the best adhesive results:
1. All surfaces to be coated should be sound, clean, dry and free of all contaminants.
2. Loose dirt and dust are best removed by a stiff bristle brush or by blowing down with dry, oil-free compressed air.
3. Oil, wax and grease should by removed by dissolving in a water-based cleaner/degreaser such as Loctite® Natural Blue Cleaner and Degreaser. Rinse thoroughly with fresh water while the dissolved solution is still wet. An alternate method is to clean with appropriate solvents such as mineral spirits as per SSPC-SP-1. It is important that the solvent be removed from the surface while still liquid and not be allowed to evaporate during the cleaning process and redeposit oil or grease on the deck. Ample solvent should be applied to the surface to completely dissolve the grease and oil. The solvent containing the dissolved grease and oil should be wiped up with clean rags before the solvent dries.
4. Depending on concentration and type, chemical contamination should be removed by detergent power washing followed by a liberal fresh water while the detergent is still wet. Allow surface to completely dry.
5. After cleaning, any remaining loose particles should be removed by brushing or blowing with dry, oil-free compressed air.
New Concrete:
1. New concrete should be properly cured for at least 30 days with good ventilation.
2. After proper curing, new floors must be swept clean and all contaminants which might interfere with the adhesion of the coating system including laitance, curing membranes, surface hardeners, greases and oils be removed.
3. An appropriate profile must be created using chemical or mechanical means.
4. The preferred method to prepare floor surfaces and to remove paint, laitance, curing membranes and surface hardeners is by mechanical removal of the same with a portable shot blast cleaning machine.
5. Chemical cleaning of laitance and unbounded particles can be accomplished by etching the surface with a muriatic acid or buffered acid solution. Follow acid manufacturer's application and safety instructions. After the acid has finished reacting with the concrete, the residue should be removed by a liberal fresh water rinse or preferably by power washing. Allow the surface to completely dry.
6. NOTE: Acid etching will not remove oil, grease or wax. If the acid does not bubble or foam when spread on the concrete, the surface should be examined for films or oil, grease, wax, curing membranes, hardeners or other sealers. If such film is present, it must be removed.
Storage:
Store product in the unopened container in a dry location. Material removed from containers may be contaminated during use. Do not return liquid to original container. Storage information may be indicated on the product container labeling. Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties. Henkel cannot assume responsibility for product which has been contaminated or stored under conditions other than those recommended.
Parameters:
Coverage:
Roller : 4.6 m² per 3.78 l Spray : 5.6 m² per 3.78 l Trowel : 3.7 m² per 3.78 l
Dry time (21 °C), hours: Heavy pedestrian traffic : 72 Light pedestrian traffic : 12
Full technical information can be found in the technical data sheet
LOCTITE PC 6261 is a single-component epoxy non-slip floor and deck coating that is designed for application in areas of heavy pedestrian traffic or light rolling traffic under typical dry service temperatures of -29 to 60°C (-20 to 140F). This high performance safety coating is both easy and fast to apply. Typical applications include a non-slip finish for concrete and steel ramps, walkways, locker rooms, loading docks, marine applications, machine rooms assembly areas and stairs. Further information about the product: biuro@woronko-kleje.pl
Steps to achieve the best adhesive results:
1. All surfaces to be coated should be sound, clean, dry and free of all contaminants.
2. Loose dirt and dust are best removed by a stiff bristle brush or by blowing down with dry, oil-free compressed air.
3. Oil, wax and grease should by removed by dissolving in a water-based cleaner/degreaser such as Loctite® Natural Blue Cleaner and Degreaser. Rinse thoroughly with fresh water while the dissolved solution is still wet. An alternate method is to clean with appropriate solvents such as mineral spirits as per SSPC-SP-1. It is important that the solvent be removed from the surface while still liquid and not be allowed to evaporate during the cleaning process and redeposit oil or grease on the deck. Ample solvent should be applied to the surface to completely dissolve the grease and oil. The solvent containing the dissolved grease and oil should be wiped up with clean rags before the solvent dries.
4. Depending on concentration and type, chemical contamination should be removed by detergent power washing followed by a liberal fresh water while the detergent is still wet. Allow surface to completely dry.
5. After cleaning, any remaining loose particles should be removed by brushing or blowing with dry, oil-free compressed air.
New Concrete:
1. New concrete should be properly cured for at least 30 days with good ventilation.
2. After proper curing, new floors must be swept clean and all contaminants which might interfere with the adhesion of the coating system including laitance, curing membranes, surface hardeners, greases and oils be removed.
3. An appropriate profile must be created using chemical or mechanical means.
4. The preferred method to prepare floor surfaces and to remove paint, laitance, curing membranes and surface hardeners is by mechanical removal of the same with a portable shot blast cleaning machine.
5. Chemical cleaning of laitance and unbounded particles can be accomplished by etching the surface with a muriatic acid or buffered acid solution. Follow acid manufacturer's application and safety instructions. After the acid has finished reacting with the concrete, the residue should be removed by a liberal fresh water rinse or preferably by power washing. Allow the surface to completely dry.
6. NOTE: Acid etching will not remove oil, grease or wax. If the acid does not bubble or foam when spread on the concrete, the surface should be examined for films or oil, grease, wax, curing membranes, hardeners or other sealers. If such film is present, it must be removed.
Storage:
Store product in the unopened container in a dry location. Material removed from containers may be contaminated during use. Do not return liquid to original container. Storage information may be indicated on the product container labeling. Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or greater than 28 °C can adversely affect product properties. Henkel cannot assume responsibility for product which has been contaminated or stored under conditions other than those recommended.
Parameters:
Coverage:
Dry time (21 °C), hours:
Full technical information can be found in the technical data sheet